[ VEA TVC CALA EN ESPAÑOL ]
Skip Navigation Links
PRODUCT CATALOG
Search Within Results ...
 
BROADBAND PRODUCTS
CABLES
COAXIAL CABLE
CONDUIT & INNERDUCT
CONNECTIVITY PRODUCTS
CONNECTORS & HEATSHRINK
CRITICAL INFRASTRUCTURE
DIGITAL SIMULCAST
DIGITAL VOICE
DROP MATERIALS
FIBER OPTICS
FTTX
HARDWARE
HEADEND EQUIPMENT
IP NETWORKING
MARATHON
MAXCELL
METRO ETHERNET
PANELS
TEST EQUIPMENT
TOOLS & SAFETY EQUIPMENT
TWISTED PAIR
UNDERGROUND EQUIPMENT
COUPLINGS
DUCT PLUGS
LOCATING PRODUCTS
LUBRICANTS
MARKERS & WARNING TAPE
PEDESTALS
PULL ROPE
PULL TAPE
UNDERGROUND ENCLOSURES
WATERPROOFING
ADVANCED SEARCH
MANUFACTURERS
ELECTRONIC CATALOGS
PRODUCT HIGHLIGHTS
OVERSTOCKS & CLOSEOUTS
SOME PRODUCTS PRESENTED IN THIS CATALOG MAY NOT BE AVAILABLE FOR WORLD-WIDE SALE. PLEASE CONTACT YOUR LOCAL TVC REPRESENTATIVE FOR FULL DETAILS.
HOME : PRODUCT CATALOG : UNDERGROUND EQUIPMENT : COUPLINGS

Vikimatic Electrofusion

EMAIL SALES ABOUT THIS PRODUCT
Vikimatic ElectrofusionThe Electrofusion System offers you an external slip connection fitting made from polyethylene. That means a non-metallic, non-corrosive joint for longer connection life. With the Electrofusion System, you get a heat fused joint that is pressure tight. In fact, tests have shown these joints to have a stronger tensile strength than that of the pipe itself. The Electrofusion System requires a minimal working area and there is on lateral movement of pipe required for joining.

I. PE to PE - Electrofusion has been used to join PE pipe for over 30 years. The joint strength has been tested for three (3) different joint performances.

1. Tensile Strength of the fusion has been proved to be stronger than pipe yield strength.
2. Pressure strength of the fusion has been proven to be stronger than the burst strength of the pipe. Joints have been tested at 340 lbs. pressure for over 38,000 hours.
3. The bond strength of the fusion has been proven under crush test to be stronger than the pipe itself.

II. PE to PVC - This is a new concept for very specialized applications. The PE does not fuse to the PVC. The joint strength is achieved by the thermal expansion of both plastics at the interface when heated. Both the PE and PVC pipe have been prepared by a serrated scraping tool creating grooves .015" deep. The PE of the coupling melts into the serrations of the PVC. The thermal expansion of both the PE and PVC creates a very tight compression.

1. Tensile strength has been tested on 2" SDR-11 PE3408 to 2" Schedule 40 PVC, resulting in the PE yielding at 3.842 lbs. of tensile. Test on 2" Schedule 40 PE3408 to 2" DB-120 PVC resulted in the PE yielding at 2,900 lbs. of tensile.
2. Pressure strength has been tested successfully at 20 psi for 24 hours. This test was to ensure a water tight seal. This joint is not to be considered a pressure rated connection.
3. Bond strength between the PE and PVC, when sectioned, is non-existent. Upon viewing the sections, it is apparent that the serrations in the PVC have created an anchor pattern. The PE from the coupling has molded into this anchor pattern and appears to have a biting affect, but when impacted the two will separate.
Vikimatic
VIEW SPECIFICATION DATA SHEET

Product Detail

See PDF for ordering information on Electrofusion and on Reducers, scrapers and vice grips.

 
 